EV & Battery Testing
Programmable DC electronic loads for battery discharge and capacity testing, EV battery and component test, capacity grading and second-life sorting.
See DC electronic loads →Solutions
Electronic test instruments for components, power and battery work — in workshops, labs and on production lines.
Programmable DC electronic loads for battery discharge and capacity testing, EV battery and component test, capacity grading and second-life sorting.
See DC electronic loads →Load and source instruments for charger and switching power supply verification — on the bench and on the production line.
See DC power supplies →LCR bridges for product R&D and component parameter analysis, DDS function generators for circuit development and teaching labs.
See signal generators →Component incoming inspection, comparator sorting for pass/fail binning and production-line testing of chargers and power supplies.
See LCR meters & bridges →Recommended Products
Core models. Datasheets and prices are quoted per enquiry.
A 3-in-1 handheld instrument for field and bench work: a 100 MHz 2-channel digital oscilloscope, an independent 20,000-count True RMS multimeter and a 25 MHz arbitrary waveform generator in one battery-powered unit. Made for power-supply and charger debugging, automotive and field service — the natural companion to our DC loads and power supplies.
The ET54A+ series is a single- and dual-channel programmable DC electronic load series, redesigned from the earlier ET5400 series with easier operation and a full set of professional test functions. High-performance chips and a high-speed, high-precision design give resolution up to 1 mV / 1 mA. The series is widely used for production-line testing of chargers, switching power supplies, linear power supplies and batteries, and in R&D test work.
| Item | ET5410A+ | ET5420A+ | ET5411A+ |
|---|---|---|---|
| Channels | Single | Dual | Single |
| Rated input power | 400 W | 400 W (200 W × 2) | 400 W |
| Input voltage | 0–150 V | 0–150 V | 0–500 V |
| Input current | 0–40 A | 0–20 A × 2 | 0–15 A |
| CV mode range | 0.1–19.999 V / 0.1–150.00 V | 0.1–19.999 V / 0.1–150.00 V | 0.1–19.999 V / 0.1–500.00 V |
| CC mode range | 0–3.000 A / 0–40.00 A | 0–3.000 A / 0–20.00 A | 0–3.000 A / 0–15.00 A |
| CR mode range | 0.05 Ω–1 kΩ / 1 kΩ–4.5 kΩ | ||
| CP mode range | 0–400 W | 0–200 W | 0–400 W |
| Battery test | CC / CR discharge · max. discharge capacity 9,999 Ah | ||
| Accuracy | CV ±(0.05 % + 0.02 % FS) · CC ±(0.05 % + 0.05 % FS) · CR / CP ±(0.1 % + 0.5 % FS) |
|---|---|
| Readback accuracy | Voltage / current ±(0.05 % + 0.1 % FS) · power ±(0.1 % + 0.5 % FS) |
| Resolution | CV 1 mV / 10 mV · CC 1 mA / 10 mA · CR 10 mΩ / 100 mΩ · CP 10 mW |
| Protections | Over-voltage > 155 V (5411A+: > 510 V) · over-current > 42 A (by model 22 / 16 A) · over-power 420 W · over-temperature 85 ℃ · short circuit CC ≦ 3 A / rated range, CV 0 V, CR ≦ 40 mΩ |
| Display | 2.8″ TFT LCD, 400 × 240 · Chinese / English · key lock |
| Interfaces | USB standard · RS-232 / RS-485 optional · DB9 external trigger input |
| Power supply | AC 110–220 V ±10 %, 45–65 Hz |
| Environment | Operating 0–40 ℃ · relative humidity < 80 % · storage −10–70 ℃ |
| Dimensions | 90 × 190 × 300 mm (W × H × D) |
The ET5407A+ series is an economical range of programmable DC electronic loads with high resolution and accuracy — 1 mV / 1 mA and 10 mV / 10 mA ranges. Nine working modes (four basic measurement modes plus five professional test modes) give a full test set, widely used for production-line testing of chargers, switching power supplies, linear power supplies and batteries.
| Item | ET5406A+ | ET5407A+ |
|---|---|---|
| Rated input power | 200 W | 200 W |
| Input voltage | 0–120 V | 0–180 V |
| Input current | 0–20 A | 0–30 A |
| CV mode range | 0.1–19.999 V / 0.1–120.00 V | 0.1–19.999 V / 0.1–180.00 V |
| CC mode range | 0–3.000 A / 0–20.00 A | 0–3.000 A / 0–30.00 A |
| CR mode range | 0.05 Ω–4.5 kΩ | |
| CP mode range | 0–200 W | |
| Mode resolution / accuracy | CV 1 mV / 10 mV, ±(0.05 % + 0.02 % FS) · CC 1 mA / 10 mA, ±(0.05 % + 0.05 % FS) · CR 10 mΩ / 1 Ω, ±(0.1 % + 0.5 % FS) · CP 10 mW, ±(0.1 % + 0.5 % FS) | |
| Dynamic test | CC / CV modes · T1 & T2: 0.05 s–99.999 s | |
| Battery test | Discharge in CC / CR modes · max. discharge capacity 9,999 Ah · resolution 1 mA / 10 mA / 10 mΩ / 1 Ω | |
| Readback | Voltage ranges as CV mode, 1 mV / 10 mV, ±(0.05 % + 0.1 % FS) · Current ranges as CC mode, 1 mA / 10 mA, ±(0.05 % + 0.1 % FS) · Power 200 W, 10 mW, ±(0.1 % + 0.5 % FS) | |
| Over-voltage protection | > 21 V / > 125 V | > 21 V / > 185 V |
| Over-current protection | > 3.1 A / > 21 A | > 3.1 A / > 31 A |
| Over-power protection | 210 W | |
| Over-temperature protection | 85 ℃ | |
| Display | LCD segment display, adjustable backlight |
|---|---|
| Interfaces | USB standard · RS-232 or RS-485 optional (one of the two) |
| Power supply | 100 Vac ±10 % – 240 Vac ±10 %, 50/60 Hz |
| Environment | Operating 0–40 ℃ · relative humidity < 80 % · storage −10–70 ℃ |
| Dimensions | 75 × 155 × 240 mm (W × H × D) |
| Standard accessories | Three-core power cord × 1 · power fuses × 2 · user manual × 1 |
The ET547X series portable DC electronic loads use a high-performance chip with a high-speed, high-accuracy design, in a rigid yet compact housing. Compared with similar products they offer a stronger price-to-performance ratio. Typical uses are production lines (switching power supplies, linear power supplies, mobile phone adapters and all kinds of batteries), research institutes, automotive electronics and aerospace.
| Item | ET5470 | ET5471 | ET5475 | ET5476 |
|---|---|---|---|---|
| Channel | Single | Single | Single | Single |
| Rated power | 80 W | 80 W | 150 W | 150 W |
| Input voltage | 0 – 80 V | 0 – 150 V | 0 – 150 V | 0 – 300 V |
| Input current | 0 – 20 A | 0 – 20 A | 0 – 20 A | 0 – 10 A |
| CV mode range | 1 – 80.00 V | 1 – 150.0 V | 1 – 150.0 V | 1 – 300.0 V |
| CV resolution | 10 mV | 10 mV | 100 mV | 100 mV |
| CV accuracy | ±(0.2 % RD + 0.2 % FS) | ±(0.2 % RD + 0.2 % FS) | ±(0.2 % RD + 0.2 % FS) | ±(0.2 % RD + 0.2 % FS) |
| CC mode range | 0 – 20.00 A | 0 – 20.00 A | 0 – 20.00 A | 0 – 10.00 A |
| CC resolution | 10 mA | 10 mA | 10 mA | 10 mA |
| CC accuracy | ±(0.2 % RD + 0.2 % FS) | ±(0.2 % RD + 0.2 % FS) | ±(0.2 % RD + 0.2 % FS) | ±(0.2 % RD + 0.2 % FS) |
| Voltage readback range | 0 – 80.00 V | 0 – 150.0 V | 0 – 150.0 V | 0 – 300.0 V |
| Voltage readback resolution | 10 mV | 10 mV | 10 mV | 100 mV |
| Voltage readback accuracy | ±(0.2 % RD + 0.2 % FS) | ±(0.2 % RD + 0.2 % FS) | ±(0.2 % RD + 0.2 % FS) | ±(0.2 % RD + 0.2 % FS) |
| Current readback range | 0 – 20.00 A | 0 – 20.00 A | 0 – 20.00 A | 0 – 10.00 A |
| Current readback resolution | 10 mA | 10 mA | 10 mA | 10 mA |
| Current readback accuracy | ±(0.2 % RD + 0.2 % FS) | ±(0.2 % RD + 0.2 % FS) | ±(0.2 % RD + 0.2 % FS) | ±(0.2 % RD + 0.2 % FS) |
| Over-voltage protection | Input cut above 82 V | Input cut above 155 V | Input cut above 155 V | Input cut above 310 V |
| Over-current protection | Input cut above 21 A | Input cut above 21 A | Input cut above 21 A | Input cut above 11 A |
| Over-power protection | 85 W | 85 W | 85 W | 155 W |
| Over-temperature protection | 85 °C | 85 °C | 85 °C | 85 °C |
| Display | High-brightness LED display |
|---|---|
| Interface | USB Type-C |
| Power supply | Built-in rechargeable battery; charging via the supplied 5 V / 3 A adapter |
| Dimensions | 90 × 116 × 165 mm |
| Weight | 0.82 kg |
The ET53 series single- and dual-channel programmable DC electronic loads use high-performance chips with a high-speed, high-precision design, providing 1 mV / 1 mA resolution. The series is widely used for production-line testing of chargers, switching power supplies, linear power supplies and batteries, and in R&D testing at research institutes.
| Item | ET5300 | ET5301 | ET5302 | ET5303 | ET5304 |
|---|---|---|---|---|---|
| Channels | Single | Single | Single | Single | Dual |
| Rated input power | 400 W | 400 W | 400 W | 400 W | 400 W |
| Input voltage | 0–150 V | 0–150 V | 0–500 V | 0–500 V | 0–150 V |
| Input current | 0–40 A | 0–60 A | 0–15 A | 0–30 A | 0–60 A (30 A per channel) |
| CV mode range | 0.1–19.999 V / 0.1–150.00 V | 0.1–19.999 V / 0.1–150.00 V | 0.1–19.999 V / 0.1–500.00 V | 0.1–19.999 V / 0.1–500.00 V | 0.1–19.999 V / 0.1–150.00 V |
| CC mode range | 0–3.000 A / 0–40.00 A | 0–6.000 A / 0–60.00 A | 0–3.000 A / 0–15.00 A | 0–3.000 A / 0–30.00 A | 0–3.000 A / 0–30.00 A |
| CR mode range | 0.05 Ω–1 kΩ / 1 kΩ–4.5 kΩ | ||||
| CP mode range | 0–400 W | 0–400 W | 0–400 W | 0–400 W | 0–200 W |
| Mode resolution / accuracy | CV 1 mV / 10 mV, ±(0.05 % + 0.02 % FS) · CC 1 mA / 10 mA, ±(0.05 % + 0.05 % FS) · CR 10 mΩ / 100 mΩ, ±(0.1 % + 0.5 % FS) · CP 10 mW, ±(0.1 % + 0.5 % FS) | ||||
| Dynamic test | CC / CV modes · T1 & T2: 50 ms–60 s | ||||
| Battery test | Discharge in CC / CR modes · max. discharge capacity 9,999 Ah · resolution 1 mA / 10 mA / 10 mΩ / 100 mΩ | ||||
| Readback | Voltage 0–19.999 V / 0–150.00 V (ET5302 / ET5303: 0–500.00 V), 1 mV / 10 mV, ±(0.05 % + 0.1 % FS) · Current ranges as CC mode, 1 mA / 10 mA, ±(0.05 % + 0.1 % FS) · Power as CP mode (ET5304: 200 W), 10 mW, ±(0.1 % + 0.5 % FS) | ||||
| Over-voltage protection | > 21 V / > 155 V | > 21 V / > 155 V | > 21 V / > 510 V | > 21 V / > 510 V | > 21 V / > 155 V |
| Over-current protection | > 3.1 A / > 41 A | > 6.1 A / > 61 A | > 16 A, cut off | > 3.1 A / > 31 A | > 31 A, cut off |
| Over-power protection | 410 W | 410 W | 410 W | 410 W | 210 W |
| Over-temperature protection | 85 ℃ | ||||
| Display | 3.5″ TFT LCD, 480 × 320 · Chinese / English |
|---|---|
| Interfaces | USB and RS-232 standard · RS-485 optional |
| Power supply | 220 Vac ±10 % / 110 Vac ±10 %, 45–65 Hz |
| Environment | Operating 0–40 ℃ · relative humidity < 80 % · storage −10–70 ℃ |
| Dimensions | 320 × 220 × 100 mm (L × W × H) |
| Weight | 4.2 kg (main unit) |
The ET5500 series high-precision programmable DC electronic loads use a standard chassis size and high-performance chips in a high-speed, high-precision design, with display resolution up to 0.1 mV / 0.1 mA. Eight standard models cover 150 W to 600 W, six mid-power models cover 1200 W to 2400 W, and four high-power models extend the range to 3000 W and 3600 W — 18 models in total. The series is widely used in automated integration testing, production-line testing of chargers, switching power supplies, linear power supplies, new-energy batteries, battery management systems and DC charging piles, and in laboratory R&D testing at research institutes.
| Item | ET5501A | ET5501B | ET5503A | ET5503B | ET5504A | ET5506A | ET5506B | ET5506C |
|---|---|---|---|---|---|---|---|---|
| Rated input power | 150 W | 150 W | 300 W | 300 W | 400 W | 600 W | 600 W | 600 W |
| Input voltage | 0–150 V | 0–500 V | 0–150 V | 0–500 V | 0–150 V | 0–150 V | 0–500 V | 0–150 V |
| Input current | 0–30 A | 0–15 A | 0–30 A | 0–15 A | 0–60 A | 0–60 A | 0–30 A | 0–120 A |
| CV mode range | 0.1–150.0 V | 0.1–500.0 V | 0.1–150.0 V | 0.1–500.0 V | 0.1–150.0 V | 0.1–150.0 V | 0.1–500.0 V | 0.1–150.0 V |
| CC mode range | 0–30.00 A | 0–15.00 A | 0–30.00 A | 0–15.00 A | 0–60.00 A | 0–60.00 A | 0–30.00 A | 0–120.00 A |
| CP mode range | 0–150 W | 0–150 W | 0–300 W | 0–300 W | 0–400 W | 0–600 W | 0–600 W | 0–600 W |
| CR mode range | 16-bit range · resolution 10 mΩ | |||||||
| Mode resolution / accuracy | CV 1 mV / 10 mV, ±(0.05 % + 0.025 % FS) · CC 0.1 mA / 1 mA (ET5506C: 1 mA / 10 mA), ±(0.05 % + 0.05 % FS) · CP 10 mW, ±(0.1 % + 0.1 % FS) · CR ±(0.1 % + 0.1 % FS) | |||||||
| Voltage readback | Ranges as input voltage · resolution 0.1 mV / 1 mV · accuracy ±(0.025 % + 0.025 % FS) | |||||||
| Current readback | Ranges as input current · resolution 0.1 mA / 1 mA (ET5506C: 1 mA / 10 mA) · accuracy ±(0.05 % + 0.05 % FS) | |||||||
| Item | ET5512A | ET5512B | ET5518A | ET5518B | ET5524A | ET5524B |
|---|---|---|---|---|---|---|
| Rated input power | 1200 W | 1200 W | 1800 W | 1800 W | 2400 W | 2400 W |
| Input voltage | 0–150 V | 0–500 V | 0–150 V | 0–500 V | 0–150 V | 0–500 V |
| Input current | 0–120 A | 0–60 A | 0–180 A | 0–90 A | 0–240 A | 0–120 A |
| Voltage ranges (small / large) | 15 V / 150 V | 15 V / 500 V | 15 V / 150 V | 15 V / 500 V | 15 V / 150 V | 15 V / 500 V |
| Current ranges (small / large) | 12 A / 120 A | 6 A / 60 A | 18 A / 180 A | 9 A / 90 A | 24 A / 240 A | 12 A / 120 A |
| Setting resolution (small / large range) | 1 mV / 1 mA · 10 mV / 10 mA | 1 mV / 1 mA · 10 mV / 1 mA | 1 mV / 1 mA · 10 mV / 10 mA | 1 mV / 1 mA · 10 mV / 10 mA | 1 mV / 1 mA · 10 mV / 10 mA | 1 mV / 1 mA · 10 mV / 10 mA |
| Display resolution | 0.1 mV / 0.1 mA | |||||
| Basic accuracy | Voltage ±(0.025 % + 0.025 % FS) · Current ±(0.05 % + 0.05 % FS) | |||||
| Item | ET5530A | ET5530B | ET5536A | ET5536B |
|---|---|---|---|---|
| Rated input power | 3000 W | 3000 W | 3600 W | 3600 W |
| Input voltage | 0–150 V | 0–500 V | 0–150 V | 0–500 V |
| Input current | 0–240 A | 0–120 A | 0–240 A | 0–120 A |
| CV mode range | 0.1–150.0 V | 0.1–500.0 V | 0.1–150.0 V | 0.1–500.0 V |
| CC mode range | 0–120.0 A | 0–120.0 A | 0–240.0 A | 0–120.0 A |
| CP mode range | 0–3000 W | 0–3000 W | 0–3600 W | 0–3600 W |
| CR mode range | 16-bit range · resolution 10 mΩ | |||
| Mode resolution / accuracy | CV 1 mV / 10 mV, ±(0.05 % + 0.025 % FS) · CC 1 mA / 10 mA, ±(0.05 % + 0.05 % FS) · CP 10 mW, ±(0.1 % + 0.1 % FS) · CR ±(0.1 % + 0.1 % FS) | |||
| Voltage readback | Ranges as input voltage · resolution 0.1 mV / 1 mV · accuracy ±(0.025 % + 0.025 % FS) | |||
| Current readback | Ranges as CC mode · resolution 0.1 mA / 1 mA · accuracy ±(0.05 % + 0.05 % FS) | |||
| Dimensions / weight | Approx. 550 × 440 × 380 mm · approx. 40 kg | |||
| Display | 4.3″ TFT LCD · Chinese / English |
|---|---|
| Interfaces | RS232 standard · SCPI and Modbus programming commands |
| Power supply | 220 Vac ±10 % or 110 Vac ±10 %, 45–65 Hz |
| Environment | Operating 10–40 ℃ · non-operating −10–60 ℃ · humidity ≤ 90 % RH (within 0–40 ℃) |
| Dimensions | Standard models: approx. 400 × 240 × 100 mm · high-power models: approx. 550 × 440 × 380 mm |
| Weight | Standard models: 4.4 kg · high-power models: approx. 40 kg |
The ET5506A is a high-precision programmable DC electronic load from the ET5500 series, built in the series standard chassis with a high-speed, high-precision design and display resolution up to 0.1 mV / 0.1 mA. Rated at 600 W with a 0–150 V / 0–60 A input, it is widely used in automated integration testing, production-line testing of chargers, switching power supplies, linear power supplies, new-energy batteries, battery management systems and DC charging piles, and in laboratory R&D testing at research institutes.
| Rated input power | 600 W |
|---|---|
| Input voltage | 0–150 V |
| Input current | 0–60 A |
| CV mode range | 0.1–150.0 V · resolution 1 mV / 10 mV · accuracy ±(0.05 % + 0.025 % FS) |
| CC mode range | 0–60 A.00 A · resolution 0.1 mA / 1 mA · accuracy ±(0.05 % + 0.05 % FS) |
| CP mode range | 0–600 W · resolution 10 mW · accuracy ±(0.1 % + 0.1 % FS) |
| CR mode range | 16-bit range · resolution 10 mΩ · accuracy ±(0.1 % + 0.1 % FS) |
| Voltage readback | Range as input voltage · resolution 0.1 mV / 1 mV · accuracy ±(0.025 % + 0.025 % FS) |
| Current readback | Range as input current · resolution 0.1 mA / 1 mA · accuracy ±(0.05 % + 0.05 % FS) |
| Test modes | CC / CV / CR / CP, CC+CV, CR+CV · battery capacity test · list test (88 groups) · short-circuit test (100 memory groups) · dynamic, auto scan, Pass / Fail, LED driver test |
| Display | 4.3″ TFT LCD · Chinese / English |
|---|---|
| Interfaces | RS232 standard · SCPI and Modbus programming commands · remote voltage sensing and current monitoring · PC data-acquisition software supported |
| Power supply | 220 Vac ±10 % or 110 Vac ±10 %, 45–65 Hz |
| Environment | Operating 10–40 ℃ · non-operating −10–60 ℃ · humidity ≤ 90 % RH (within 0–40 ℃) |
The ET5506B is a high-precision programmable DC electronic load from the ET5500 series, built in the series standard chassis with a high-speed, high-precision design and display resolution up to 0.1 mV / 0.1 mA. Rated at 600 W with a 0–500 V / 0–30 A input, it is widely used in automated integration testing, production-line testing of chargers, switching power supplies, linear power supplies, new-energy batteries, battery management systems and DC charging piles, and in laboratory R&D testing at research institutes.
| Rated input power | 600 W |
|---|---|
| Input voltage | 0–500 V |
| Input current | 0–30 A |
| CV mode range | 0.1–500.0 V · resolution 1 mV / 10 mV · accuracy ±(0.05 % + 0.025 % FS) |
| CC mode range | 0–30 A.00 A · resolution 0.1 mA / 1 mA · accuracy ±(0.05 % + 0.05 % FS) |
| CP mode range | 0–600 W · resolution 10 mW · accuracy ±(0.1 % + 0.1 % FS) |
| CR mode range | 16-bit range · resolution 10 mΩ · accuracy ±(0.1 % + 0.1 % FS) |
| Voltage readback | Range as input voltage · resolution 0.1 mV / 1 mV · accuracy ±(0.025 % + 0.025 % FS) |
| Current readback | Range as input current · resolution 0.1 mA / 1 mA · accuracy ±(0.05 % + 0.05 % FS) |
| Test modes | CC / CV / CR / CP, CC+CV, CR+CV · battery capacity test · list test (88 groups) · short-circuit test (100 memory groups) · dynamic, auto scan, Pass / Fail, LED driver test |
| Display | 4.3″ TFT LCD · Chinese / English |
|---|---|
| Interfaces | RS232 standard · SCPI and Modbus programming commands · remote voltage sensing and current monitoring · PC data-acquisition software supported |
| Power supply | 220 Vac ±10 % or 110 Vac ±10 %, 45–65 Hz |
| Environment | Operating 10–40 ℃ · non-operating −10–60 ℃ · humidity ≤ 90 % RH (within 0–40 ℃) |
The ET5506C is a high-precision programmable DC electronic load from the ET5500 series, built in the series standard chassis with a high-speed, high-precision design and display resolution up to 0.1 mV / 0.1 mA. Rated at 600 W with a 0–150 V / 0–120 A input, it is widely used in automated integration testing, production-line testing of chargers, switching power supplies, linear power supplies, new-energy batteries, battery management systems and DC charging piles, and in laboratory R&D testing at research institutes.
| Rated input power | 600 W |
|---|---|
| Input voltage | 0–150 V |
| Input current | 0–120 A |
| CV mode range | 0.1–150.0 V · resolution 1 mV / 10 mV · accuracy ±(0.05 % + 0.025 % FS) |
| CC mode range | 0–120.00 A · resolution 1 mA / 10 mA · accuracy ±(0.05 % + 0.05 % FS) |
| CP mode range | 0–600 W · resolution 10 mW · accuracy ±(0.1 % + 0.1 % FS) |
| CR mode range | 16-bit range · resolution 10 mΩ · accuracy ±(0.1 % + 0.1 % FS) |
| Voltage readback | Range as input voltage · resolution 0.1 mV / 1 mV · accuracy ±(0.025 % + 0.025 % FS) |
| Current readback | Range as input current · resolution 1 mA / 10 mA · accuracy ±(0.05 % + 0.05 % FS) |
| Test modes | CC / CV / CR / CP, CC+CV, CR+CV · battery capacity test · list test (88 groups) · short-circuit test (100 memory groups) · dynamic, auto scan, Pass / Fail, LED driver test |
| Display | 4.3″ TFT LCD · Chinese / English |
|---|---|
| Interfaces | RS232 standard · SCPI and Modbus programming commands · remote voltage sensing and current monitoring · PC data-acquisition software supported |
| Power supply | 220 Vac ±10 % or 110 Vac ±10 %, 45–65 Hz |
| Environment | Operating 10–40 ℃ · non-operating −10–60 ℃ · humidity ≤ 90 % RH (within 0–40 ℃) |
The ET4400 and ET4500 series LCR meters are component parameter analysers designed on the automatic balance bridge principle. With a 10 Hz – 100 kHz test bandwidth, continuously adjustable frequency, 0.1 % basic measurement accuracy and a binning function, they provide accurate, complete measurement and analysis for most components and materials — widely used in product R&D, incoming component inspection and in-line production sorting.
| Item | ET4401 | ET4402 | ET4410 | ET4501 | ET4502 | ET4510 |
|---|---|---|---|---|---|---|
| Test frequency range | Up to 10 kHz | Up to 20 kHz | Up to 100 kHz | 10 Hz – 10 kHz | 10 Hz – 20 kHz | 10 Hz – 100 kHz |
| Test frequency points | 10 fixed points (100, 120, 200, 400, 800 Hz, 1, 2, 4, 8, 10 kHz) | 12 fixed points (100, 120, 200, 400, 800 Hz, 1, 2, 4, 8, 10, 15, 20 kHz) | 16 fixed points (100, 120, 200, 400, 800 Hz, 1, 2, 4, 8, 10, 15, 20, 40, 50, 80, 100 kHz) | User-defined frequency, continuously adjustable in 1 Hz steps | ||
| Basic accuracy | 0.1 % | |||||
| Display digits | Main parameter 5 digits · secondary parameter 5 digits | |||||
| Measurement parameters | Main: L / C / R / Z · secondary: X / D / Q / θ / ESR | |||||
| Measurement display range | L: 0 µH – 9999 H · C: 0 pF – 99.999 mF · R: 0 Ω – 99.99 MΩ | |||||
| Measurement display speed | 2/s (slow) · 5/s (medium) · 10/s (fast) | |||||
| Internal bias | 0 – 1500 mV, adjustable in 1 mV steps | |||||
| Test level | 6 fixed levels (0.1 V, 0.3 V, 0.6 V, 1 V, 1.5 V, 2 V) | 10 mV – 2000 mV, continuously adjustable in 1 mV steps | ||||
| Signal source output impedance | 30 Ω, 100 Ω | |||||
| Calibration | Open-circuit calibration, short-circuit calibration | |||||
| Screening (tolerance) function | −100 % to +100 %, with fixed points at ±10 %, ±25 %, ±50 % | |||||
| Comparator binning | 5 bins — 3 pass bins, 1 fail bin, 1 AUX bin | |||||
| Display | 3.5-inch TFT LCD | |||||
| Dedicated test functions | DC resistance (DCR) measurement, electrolytic capacitor measurement | |||||
| Standard interfaces | RS232, USB Device, Handler | |||||
The ET430 series handheld LCR meter combines a 2.8-inch TFT display, flexible key operation and full-speed USB communication in one compact unit, powered by a large-capacity lithium battery for long working hours. Beyond a full set of measurement parameters, it offers deviation measurement and sorting, with continuously adjustable output frequency; basic accuracy is 0.2 % or 0.3 % depending on model.
| Item | ET430B | ET430 | ET431 | ET432 | ET433 |
|---|---|---|---|---|---|
| Frequency range (max) | 10 kHz | 100 kHz | 10 kHz | 100 kHz | 10 Hz – 100 kHz |
| Test frequency points | 4 fixed points (100 Hz, 120 Hz, 1 kHz, 10 kHz) | 6 fixed points (100 Hz, 120 Hz, 1 kHz, 10 kHz, 40 kHz, 100 kHz) | 4 fixed points (100 Hz, 120 Hz, 1 kHz, 10 kHz) | 6 fixed points (100 Hz, 120 Hz, 1 kHz, 10 kHz, 40 kHz, 100 kHz) | User-defined, continuously adjustable in 1 Hz steps |
| Basic accuracy | 0.3 % | 0.3 % | 0.2 % | 0.2 % | 0.2 % |
| Display | 2.8-inch TFT LCD | ||||
| Display digits | Main parameter 5 digits · secondary parameter 5 digits | ||||
| Measurement parameters | Main: L / C / R / Z · secondary: X / D / Q / θ / ESR | ||||
| Electrolytic capacitor mode | No | Yes | Yes | Yes | Yes |
| DCR mode | No | No | Yes | Yes | Yes |
| Measurement display range | L: 0 µH – 2000 H · C: 0 pF – 20.000 mF · R: 0 Ω – 20.000 MΩ | ||||
| Measurement display speed | Slow, medium, fast | ||||
| Internal bias | None | 0.1 V, 0.3 V, 0.6 V | 0 mV – 1000 mV adjustable, 1 mV steps | ||
| Test level | 0.6 V, 1 V | 0.3 V, 0.6 V, 1 V | 0.1 V, 0.3 V, 0.6 V, 1 V | 10 mV – 1100 mV, adjustable in 1 mV steps | |
| Calibration | Open-circuit calibration, short-circuit calibration | ||||
| Screening function | Limit range settable 1 % – 50 %, fixed points at 1 %, 5 %, 10 %, 20 % | ||||
| Deviation measurement | Percentage deviation between the measured component and the set nominal value is calculated and displayed | ||||
| Other | Adjustable backlight brightness, settable auto power-off time, Chinese / English selectable | USB Type-C communication, built-in large-capacity lithium battery | |||
A handheld digital capacitance meter with auto ranging for component testing and incoming inspection. Data hold, relative mode and automatic capacitor discharge are built in, with an LCD backlight for dim benches.
| Display | 2000 counts · LCD 40 × 22 mm |
|---|---|
| Capacitance range 1 | 200 mV / 2 V / 20 V / 200 V / 600 V · accuracy ±(1.0 % + 10 d) |
| Capacitance range 2 | 2000 pF / 20 nF / 200 nF / 2 µF / 20 µF / 200 µF · accuracy ±(0.5 % + 5 d) |
| Capacitance range 3 | 2000 µF · accuracy ±(2.0 % + 10 d) |
| Capacitance range 4 | 20 mF · accuracy ±(4.0 % + 10 d) |
| Range select | Auto range |
| Data hold | Yes |
| Relative mode | Yes |
| Capacitance auto discharge | Yes |
| LCD backlight | Yes |
| Auto power off | Yes |
| Battery | 6F22 9 V |
| Product size | 140 × 70.6 × 31 mm |
| Product weight | 200 g |
A tweezer-style SMD tester for resistance and capacitance measurement directly on components — in-circuit checks, sorted parts and rework benches. The gold tweezer tips grip chip components while the 4000-count display reads the value.
| Range | Resolution | Accuracy |
|---|---|---|
| 400 Ω | 0.1 Ω | ±(0.5 % + 3 d) |
| 4 kΩ | 0.001 kΩ | |
| 40 kΩ | 0.01 kΩ | |
| 400 kΩ | 0.1 kΩ | |
| 4 MΩ | 0.001 MΩ | |
| 40 MΩ | 0.01 MΩ |
| Range | Resolution | Accuracy |
|---|---|---|
| 4 nF | 0.001 nF | ±(2.5 % + 3 d) |
| 40 nF | 0.01 nF | |
| 400 nF | 0.1 nF | |
| 4 µF | 0.001 µF | |
| 40 µF | 0.01 µF | ±(3.0 % + 3 d) |
| 400 µF | 0.1 µF | |
| 4 mF | 0.001 mF | ±(10.0 % + 5 d) |
| 40 mF | 0.01 mF |
| Display | 4000 counts · LCD backlight |
|---|---|
| Safety | CAT III 300 V |
| Battery | 1 × CR2032 |
| Product size | 177 × 33 × 18 mm |
| Product weight | 65 g |
The ET3500 series precision LCR meter is a high-precision component parameter analyser designed on the automatic balance bridge principle. Its 10 Hz – 1 MHz test bandwidth with continuously adjustable frequency, 0.05 % basic measurement accuracy, automatic level control, list scan and binning functions provide accurate, complete measurement and analysis for most components and materials — widely used in product R&D, incoming component inspection and in-line production sorting.
| Item | ET3510 | ET3505 | ET3503 | ET3502 | ET3501 |
|---|---|---|---|---|---|
| Frequency range | 10 Hz – 1 MHz | 10 Hz – 500 kHz | 10 Hz – 300 kHz | 10 Hz – 200 kHz | 10 Hz – 100 kHz |
| Test frequency points | User-defined frequency, continuously adjustable in 1 mHz steps | ||||
| Test level range | 10 mV – 2000 mVrms, 1 mV steps, continuously adjustable | ||||
| Basic accuracy | 0.05 % | ||||
| Display | 6½-digit display resolution | ||||
| Frequency resolution & accuracy | Resolution 1 mHz · accuracy 0.01 % | ||||
| Test parameters | Cp-D, Cp-Q, Cp-G, Cp-Rp, Cs-D, Cs-Q, Cs-Rs, Lp-D, Lp-Q, Lp-G, Lp-Rp, Ls-D, Ls-Q, Ls-Rs, Rs-Xs, |Z|-θr, |Z|-θd, |Y|-θr, |Y|-θd, G-B | ||||
| Measurement display speed (≥100 Hz) | Fast 50/s (20 ms) · medium 10/s (100 ms) · slow 1.25/s (800 ms) | ||||
| Custom measurement speed (≥1 kHz) | User-settable, 0.5/s – 200/s | ||||
| LCR parameter display ranges | Cp, Cs: 0.001000 pF – 99.9999 F · Lp, Ls: 0.001000 nH – 99.9999 kH · Rp, Rs, |Z|, Xs: 0.001000 mΩ – 999.999 MΩ · G, B, |Y|: 0.001000 µS – 999.999 kS · θr: ±0.000001 rad – 3.14159 rad · θd: ±0.000001 deg – 179.9999 deg · D: ±0.000001 – 9.99999 · Q: ±0.001 – 99999.9 | ||||
| Voltage measurement | Resolution 1 mV · accuracy 5 % + 5 mV | ||||
| Test signal current | Range 100 µArms – 20 mArms · resolution 10 µA · accuracy 5 % + 50 µA | ||||
| Signal source output impedance | 30 Ω, 100 Ω | ||||
| Comparator | 8 pass bins, 1 fail bin, 1 AUX bin | ||||
| Trigger modes | Internal, manual, external, bus | ||||
| Math operations | Delta (absolute value), Delta% (percentage), direct reading | ||||
| Calibration | Self-calibration, open, short, load, 100 user-defined frequency points | ||||
| List scan | 10-point list scan test | ||||
| Standard interfaces | LAN, RS232, USB Host, USB Device, Handler (GPIB optional) | ||||
The ET3300 series dual-channel function / arbitrary waveform generator is designed with direct digital synthesis (DDS) technology to produce precise, stable, low-distortion output signals.
| Item | ET3315 | ET3325 | ET3340 | ET3360 |
|---|---|---|---|---|
| Sine wave | 1 µHz – 15 MHz | 1 µHz – 25 MHz | 1 µHz – 40 MHz | 1 µHz – 60 MHz |
| Square wave | 1 µHz – 15 MHz | |||
| Ramp (triangle) | 1 µHz – 15 MHz | |||
| Pulse wave | 100 µHz – 6 MHz | |||
| Arbitrary wave | 1 µHz – 6 MHz | |||
| Noise (−3 dB) | 7 MHz bandwidth | |||
| Frequency | Resolution 1 µHz · accuracy ±5 ppm · stability ±1 ppm / 3 h | |||
| Waveform types | Sine, square, ramp, pulse, noise, arbitrary (incl. DC) · 12 built-in waveforms and 50 user-defined waveforms · waveform length 8192 points · sampling rate 200 MSa/s · vertical resolution 13 bit | |||
| Sine characteristics | Harmonic distortion ≥45 dBc (<1 MHz), 40 dBc (1 – 20 MHz) · total distortion <0.8 % (20 Hz – 20 kHz, 0 dBm) | |||
| Square characteristics | Rise / fall time <20 ns · overshoot <5 % · duty cycle 1 % – 99 % (freq <100 kHz), 20 % – 80 % (100 kHz – 5 MHz), 40 % – 60 % (≥5 MHz), 0.1 % resolution | |||
| Pulse characteristics | Pulse width min 20 ns, 1 ns resolution · min edge transition 20 ns · overshoot <5 % · jitter 6 ns + 0.1 % of period | |||
| Ramp characteristics | Linearity ≥98 % (0.01 Hz – 10 kHz) · symmetry 0.0 – 100.0 %, resolution 0.1 % | |||
| Amplitude range | 2 mVpp – 20 Vpp (freq <10 MHz) · 2 mVpp – 10 Vpp (10 MHz ≤ freq <30 MHz) · 2 mVpp – 5 Vpp (freq ≥30 MHz) | |||
The ET3300C series is an economy dual-channel function / arbitrary waveform generator built on direct digital synthesis (DDS) technology, producing stable, precise output signals. It provides CH1 and CH2 outputs; both channels can output basic and arbitrary waveforms, and one channel can produce modulated output while the other outputs a basic waveform.
| Item | ET3320C | ET3340C | ET3360C |
|---|---|---|---|
| Sine wave | 1 µHz – 20 MHz | 1 µHz – 40 MHz | 1 µHz – 60 MHz |
| Square wave | 1 µHz – 15 MHz | ||
| Ramp (triangle) | 1 µHz – 15 MHz | ||
| Pulse wave | 100 µHz – 6 MHz | ||
| Arbitrary wave | 1 µHz – 6 MHz | ||
| Frequency | Resolution 1 µHz · accuracy ±20 ppm · stability ±1 ppm / 3 h | ||
| Waveform types | Sine, square, ramp, pulse, noise, arbitrary (incl. DC) · 32 built-in arbitrary waveforms plus 50 user-defined waveforms · waveform length 8192 points · sampling rate 200 MSa/s · vertical resolution 13 bit | ||
| Sine characteristics | Harmonic suppression ≥45 dBc (<1 MHz), ≥40 dBc (1 – 20 MHz) · total distortion <0.8 % (20 Hz – 20 kHz, 0 dBm) | ||
| Square characteristics | Rise / fall time <20 ns · overshoot <5 % · duty cycle 1 % – 99 % (freq <100 kHz), 20 % – 80 % (100 kHz – 5 MHz), 40 % – 60 % (≥5 MHz), 0.1 % resolution | ||
| Pulse characteristics | Pulse width min 20 ns, 1 ns resolution · min edge transition 20 ns · overshoot <5 % · jitter 6 ns + 0.1 % of period | ||
| Ramp characteristics | Linearity ≥98 % (0.01 – 10 kHz) · symmetry 0.0 – 100.0 %, resolution 0.1 % | ||
| Amplitude range | 2 mVpp – 20 Vpp (freq <10 MHz) · 2 mVpp – 10 Vpp (10 MHz ≤ freq <30 MHz) · 2 mVpp – 5 Vpp (freq ≥30 MHz) | ||
The ET3260 series is a 6½-digit benchtop digital multimeter with a 3.5-inch high-resolution colour display, high accuracy, fast measurement and an intelligent operating system. Its dual reference calibration feature lets the user complete full-function calibration with only one 10 V standard voltage and one 10 kΩ standard resistor, in under one hour in total. The ET3260 and ET3260A share the same measurement specification; they differ in input terminals and standard interfaces (see the table below).
| Item | ET3260 | ET3260A |
|---|---|---|
| Display | 3.5″ TFT colour LCD, 480 × 320, 16M colours · 6½ digits | |
| Signal terminals | Front / rear test terminals | Front test terminals |
| Interfaces | RS232 · LAN · USB Device · USB Host · Trig IN/OUT · GPIB (IEEE-488) | RS232 · LAN · USB Device · USB Host · Trig IN/OUT |
| Max. speed | 2500 readings/s · uncertainty ±(% of reading + % of range) | |
| DCV | Uncertainty 0.0035 + 0.0005 · range 0 mV – 1000 V · best resolution 100 nV | |
| ACV | Uncertainty 0.06 + 0.03 · range 1 mV – 750 V · best resolution 100 nV · frequency range 3 Hz – 300 kHz | |
| DCI | Uncertainty 0.05 + 0.006 · range 0 µA – 12 A · best resolution 10 pA | |
| ACI | Uncertainty 0.10 + 0.04 · range 1 µA – 12 A · best resolution 100 pA · frequency range 3 Hz – 10 kHz | |
| Resistance | Uncertainty 0.01 + 0.001 · range 0 Ω – 1 GΩ · best resolution 10 µΩ | |
| Frequency / period | Uncertainty 0.01 % · range 3 Hz – 1 MHz · best resolution 1 µHz | |
| Capacitance | Uncertainty 1 + 0.3 · range 0 nF – 100 mF · best resolution 1 pF | |
| Diode / continuity | Yes | |
| Ratio (DC:DC) | Reference range 100 mV – 10 V · input range 100 mV – 1000 V | |
| Temperature | Platinum resistor, thermocouple, user-defined sensor · best resolution 0.001 °C | |
| Math functions | Relative (ax + b), max / min / average, standard deviation, dB, dBm, reading hold, limit test | |
| Graphics | Histogram, trend chart, history curve | |
| Programming | SCPI — compatible with Agilent 34401A / 34410A and Fluke 45 command sets | |
| Data storage | 512K | |
| Power supply | 220 V AC ±10 % or 110 V AC ±10 %, 45 – 65 Hz · power consumption < 20 W | |
| Environment | Operating temperature −5 °C to +45 °C · humidity 5 % – 85 % RH | |
| Size & weight | 265 × 102 × 335 mm (W × H × D) · 3.2 kg | |
The ET3255 series is a full-function, stable true-RMS benchtop digital multimeter with dual display. Built on an STM32 chip with an external dual-integration ADC for accurate measurement and stable performance, it has a 3.5-inch 320×480 high-resolution TFT display with clear, rich readings. Mains powered with full-function, full-range overload protection, it is an essential instrument for electricians, electronics engineers and university laboratories.
| Item | ET3255 | ET3256 | ET3257 | ET3258 |
|---|---|---|---|---|
| Reading display | 220000 (5½) | 220000 (5½) | 550000 (5 4/5) | 660000 (5⅚) |
| Display speed | Fast / Medium / Slow | |||
| DC voltage | Range 1000 V · best resolution 1 µV · uncertainty ±(0.015 % + 3) | Range 1100 V · best resolution 1 µV · uncertainty ±(0.01 % + 3) | ||
| DC current range | 10 A | 12 A | ||
| DC current | Best resolution 1 nA · uncertainty ±(0.05 % + 10) | Best resolution 1 nA · uncertainty ±(0.03 % + 10) | ||
| AC voltage range | 750 V | 800 V | ||
| AC voltage | Frequency range — · best resolution 1 µV · uncertainty ±(0.2 % + 100) | Frequency range 20 Hz – 100 kHz · best resolution 1 µV · uncertainty ±(0.2 % + 100) | Frequency range 20 Hz – 100 kHz · best resolution 1 µV · uncertainty ±(0.1 % + 100) | |
| AC current range | 10 A | 12 A | ||
| AC current | Frequency range 20 Hz – 10 kHz · best resolution 1 nA · uncertainty ±(0.2 % + 100) | Frequency range 20 Hz – 10 kHz · best resolution 1 nA · uncertainty ±(0.1 % + 100) | ||
| Resistance range | 200 MΩ | 1 GΩ | ||
| Resistance | Best resolution 1 mΩ · uncertainty ±(0.015 % + 3) | Best resolution 1 mΩ · uncertainty ±(0.01 % + 3) | ||
| Capacitance | Range 10 mF · best resolution 1 pF · uncertainty ±(1 % + 5) | |||
| Frequency | Range 20 MHz · best resolution 0.0001 Hz · uncertainty ±(0.005 % + 3) | |||
| Power supply | 220 V AC ±10 % or 110 V AC ±10 %, 45 – 65 Hz | |||
|---|---|---|---|---|
| Operating environment | 0 – 40 °C, relative humidity < 80 % | |||
| Storage | −10 – 50 °C, relative humidity < 80 % | |||
| Display | 3.5″ TFT LCD, 480 × 320, 16M colours | |||
| Size & weight | 265 × 105 × 305 mm (W × H × D) · 2.3 kg | |||
The ET3240 series is a full-function, stable true-RMS benchtop digital multimeter with dual display. Built on an STM32 chip with an external dual-integration ADC, it provides accurate measurement and stable performance, with a 3.5-inch 320×480 high-resolution TFT display giving clear, rich readings. Mains powered with full-function, full-range overload protection, it is an essential instrument for electricians, electronics enthusiasts and engineers, and university laboratories.
| Item | ET3240 | ET3241 | ET3241B | ET3242 | ET3243 |
|---|---|---|---|---|---|
| Reading display | 22000 counts | 22000 counts | 44000 counts | 55000 counts | 66000 counts |
| Display speed | Fast / Medium / Slow | ||||
| DC voltage range | 1000 V | 1100 V | |||
| DC voltage | Best resolution — · uncertainty ±(0.05 % + 3) | Best resolution 10 µV · uncertainty ±(0.05 % + 3) | Best resolution 10 µV · uncertainty ±(0.02 % + 3) | ||
| DC current range | 10 A | 12 A | |||
| DC current | Best resolution — · uncertainty ±(0.35 %) | Best resolution 10 nA · uncertainty ±(0.1 % + 3) | Best resolution 10 nA · uncertainty ±(0.05 % + 3) | ||
| AC voltage range | 750 V | 800 V | |||
| AC voltage | Frequency range — · best resolution — · uncertainty ±(0.8 % + 80) | Frequency range 40 Hz – 100 kHz · best resolution 10 µV · uncertainty ±(0.2 % + 20) | |||
| AC current range | 10 A | 12 A | |||
| AC current | Frequency range — · best resolution — · uncertainty ±(0.8 % + 80) | Frequency range 40 Hz – 10 kHz · best resolution 10 nA · uncertainty ±(0.3 % + 3) | |||
| Resistance range | 200 MΩ | 1 GΩ | |||
| Resistance | Best resolution — · uncertainty ±(0.1 % + 6) | Best resolution — · uncertainty ±(0.05 % + 5) | Best resolution 10 mΩ · uncertainty ±(0.04 % + 5) | Best resolution 10 mΩ · uncertainty ±(0.03 % + 5) | |
| Capacitance | Range 10 mF · best resolution 10 pF · uncertainty ±(3.5 % + 30) | Range 10 mF · best resolution 10 pF · uncertainty ±(2 % + 5) | |||
| Frequency | Range 20 MHz · best resolution 0.001 Hz · uncertainty ±(0.2 % + 10) | Range 20 MHz · best resolution 0.001 Hz · uncertainty ±(0.05 % + 3) | Range 20 MHz · best resolution 0.001 Hz · uncertainty ±(0.02 % + 3) | Range 20 MHz · best resolution 0.001 Hz · uncertainty ±(0.01 % + 3) | |
| Power supply | 220 V AC ±10 % or 110 V AC ±10 %, 45 – 65 Hz | ||||
|---|---|---|---|---|---|
| Operating environment | 0 – 40 °C, relative humidity < 80 % | ||||
| Storage | −10 – 50 °C, relative humidity < 80 % | ||||
| Display | 3.5″ TFT LCD, 480 × 320 | ||||
| Size & weight | 265 × 105 × 305 mm (W × H × D) · 2.3 kg | ||||
The ET51 series DC low resistance testers measure DC medium and low-value resistances of all kinds: transformer and other winding resistances, relay contact resistance, cable conductor resistance, bonding resistance between metal parts, fuses, conductive rubber and similar parts. A large LCD reads clearly; ranges run from 20 mΩ to 20 kΩ (2 MΩ optional) with seven ranges (nine optional). Built-in sorting with sorting-result output suits production-line testing, and RS232 and Handler interfaces support communication and control from a PC, PLC or other host.
| Item | ET510 | ET511 | ET512 | ET513 |
|---|---|---|---|---|
| Test range | 10 µΩ–5 kΩ | 10 µΩ–20 kΩ | 10 µΩ–200 kΩ | 10 µΩ–2 MΩ |
| Basic accuracy | 0.1 % + 3 digits | |||
| Minimum resolution | 10 µΩ | |||
| Max. test current | 100 mA | |||
| Display modes | Direct reading / percentage | |||
| Test speed | Slow: 8 readings/s · fast: 15 readings/s | |||
| Dedicated function | Sorting and comparator alarm | |||
| Trigger modes | Internal, manual, external | |||
| Open-circuit voltage | < 5 V | |||
| Range mode | Auto / lock | |||
| Interfaces (standard) | RS232, Handler | |||
| Range | 20 mΩ | 200 mΩ | 2 Ω | 20 Ω | 200 Ω | 2 kΩ | 5 kΩ | 20 kΩ | 200 kΩ | 2 MΩ |
|---|---|---|---|---|---|---|---|---|---|---|
| Test current | 100 mA | 100 mA | 10 mA | 1 mA | 100 µA | 100 µA | 100 µA | 100 mA | 10 µA | 1 µA |
| Resolution | 10 µΩ | 10 µΩ | 100 µΩ | 1 mΩ | 10 mΩ | 100 mΩ | 1 Ω | 1 Ω | 10 Ω | 100 Ω |
| Power supply | 100–240 V AC, 45–65 Hz |
|---|---|
| Display | 5″ LCD |
| Working environment | Temperature 5–40 ℃ · humidity < 80 % RH |
| Interfaces | RS232, Handler (standard) |
| Dimensions | 230 × 30 × 122 mm |
The ET52X series handheld DC low resistance testers are high-accuracy, wide-range portable instruments with a built-in lithium battery, so precise measurements of passive components can be made anywhere. A 3.5-inch TFT LCD makes readings easy to take. They measure DC low and medium resistance of all kinds: transformer and other winding resistance, relay and other contact resistance, cable and conductor resistance, bonding resistance between metal parts, fuses, conductive rubber and similar DC resistances.
| Item | ET520 | ET521 | ET522 | ET523 |
|---|---|---|---|---|
| Measurement range | 10 µΩ – 5 kΩ | 10 µΩ – 20 kΩ | 10 µΩ – 200 kΩ | 10 µΩ – 2 MΩ |
| Basic accuracy | 0.1 % ± 3 counts | |||
| Minimum resolution | 10 µΩ | |||
| Maximum test current | 100 mA | |||
| Display mode | Direct reading or percentage | |||
| Sorting function | Pass / fail judgement of the device under test | |||
| Trigger mode | Single / continuous | |||
| Test terminals | Four-terminal measurement | |||
| Ranging | Auto / manual | |||
| Open-circuit voltage | < 5 V | |||
| Power supply | Built-in rechargeable battery, or 5 V / 1 A adapter (charging) |
|---|---|
| Display | 3.5-inch TFT LCD, 480 × 320 |
| Operating environment | 5–40 °C · relative humidity ≤ 80 % |
| Interface | USB Type-C |
| Dimensions | 210 × 110 × 34 mm (L × W × H) |
The YTE610 three-phase energy meter field calibrator is a portable instrument designed for on-site verification of single- and three-phase active and reactive energy meters — inductive and electronic — and of many other electrical instruments. It lets utility metering departments verify meter errors on site without removing the meter or cutting the power, and gives electricity-inspection departments a practical tool for investigating electricity theft. It also checks metering installation wiring, tests metering CT ratio and polarity, and measures user power quality — voltage and current harmonics, total harmonic distortion and voltage unbalance.
| Item | YTE610-10 | YTE610-30 | YTE610-100 |
|---|---|---|---|
| Clamp CT range (AC input) | 10 A | 30 A | 100 A |
| Custom sensors | Custom sensor function — clamp CTs of other ranges can be selected as required | ||
| Direct current input range (AC / DC) | 0–10 A · auto ranges 1 A, 5 A, 10 A | ||
| Voltage input range (AC / DC) | 0–750 V · auto ranges 57.7 V, 100 V, 220 V, 380 V, 750 V | ||
| Verification accuracy — voltage | ±0.05 % | ||
| Verification accuracy — current | Direct input ±0.05 % · clamp CT ±0.5 % | ||
| Verification accuracy — active power | Direct input ±0.05 % · clamp CT ±0.5 % | ||
| Verification accuracy — reactive power | Direct input ±0.3 % · clamp CT ±1.0 % | ||
| Verification accuracy — active energy | Direct input ±0.05 % · clamp CT ±0.5 % | ||
| Verification accuracy — reactive energy | Direct input ±0.3 % · clamp CT ±1.0 % | ||
| Frequency measurement | Range 10–100 Hz · resolution 0.001 Hz · accuracy ±0.01 Hz | ||
| Phase measurement | Range 0–359.999° · accuracy ±0.05° | ||
| Energy pulse input | Max. pulse input frequency 1 kHz · constant settable 1–100000 · divider coefficient 1–9999 | ||
| Harmonic measurement (2nd–50th) | Fundamental voltage / current amplitude accuracy ±0.2 % · phase difference accuracy ±0.1° · harmonic content accuracy ±0.2 % · total harmonic distortion ±0.2 % | ||
| Three-phase unbalance | ±0.2 % | ||
| Power supply | Battery, or 5 V / 3 A adapter (charging) |
|---|---|
| Power consumption | ≤ 3 W |
| Display | 5-inch TFT LCD, 800 × 480 |
| Interfaces | Standard: RS232, USB Host, USB Device, LAN · Optional: WiFi, micro printer |
| Dimensions | 300 × 270 × 165 mm (L × W × H) |
| Weight | 2.8 kg |
| Working temperature | −25 °C to +55 °C · relative humidity 15–85 % |
The YTE215X series earth resistance testers are professional instruments for testing the earth resistance of electrical equipment. Controlled by an intelligent microchip, they offer high accuracy and high reliability, and measure the earth resistance of grounding installations in power systems, electrical equipment and lightning-protection devices. They also measure AC earth voltage. The series has two models: YTE2150 (200 Ω) and YTE2151 (2000 Ω).
| Range | YTE2150 | YTE2151 | Resolution |
|---|---|---|---|
| 20 Ω | ±2 % rdg ± 5 dgt | ±2 % rdg ± 5 dgt | 0.01 Ω |
| 200 Ω | ±2 % rdg ± 3 dgt | ±2 % rdg ± 3 dgt | 0.1 Ω |
| 2000 Ω | — | ±2 % rdg ± 3 dgt | 1 Ω |
| Power supply | Lithium battery (3.7 V, 1500 mAh), or 5 V / 1 A adapter |
|---|---|
| Charging interface | USB Type-C, 5 V |
| Display | Segment LCD |
| Operating environment | 0 °C to +40 °C · relative humidity < 75 % RH |
| Dimensions | 170 × 105 × 50 mm (L × W × H) |
| Weight | Net approx. 0.3 kg |
| Overload protection | Earth resistance ranges 600 V AC (10 s) · earth voltage range 750 V AC (30 s) |
| Withstand voltage | 1500 V AC between leads and housing for 1 minute, no flashover |
| Open-circuit voltage | Approx. 50 V |
| Test frequency / current | Approx. 820 Hz · approx. 3 mA (AC) on the 20 Ω range |
The YTE216X series are multi-function digital insulation resistance testers designed for field testing — portable instruments with high accuracy, high stability, low power consumption and easy operation. They measure the insulation resistance of motors, transformers, cables, switches, electrical equipment and insulating materials, for the maintenance, testing and inspection of all kinds of electrical equipment. They also measure AC / DC voltage and low resistance.
| Item | YTE2160 | YTE2161 |
|---|---|---|
| Rated voltage | 100 V, 200 V, 500 V, 1000 V | 100 V, 200 V, 500 V, 1000 V |
| Output voltage accuracy | ±10 % ± 10 V | ±10 % ± 10 V |
| Insulation resistance range | 0–10 GΩ | 0–100 GΩ |
| Measurement functions | DC voltage, AC voltage, low resistance, insulation resistance | |
| Absorption ratio (DAR) test | Yes | |
| Polarization index (PI) test | Yes | |
| Short-circuit current | ≤ 2 mA | |
| DC voltage input impedance | 10 MΩ | |
| AC voltage input impedance | 5 MΩ | |
| Power supply | 3.7 V, 1500 mAh lithium battery | |
| Dimensions | 155 × 105 × 45 mm | |
| Display | LCD, maximum reading 9999 | |
| Data storage | 100 readings | |
| Low battery | Indication when the battery voltage falls below 3.2 V — charge in time | |
| Output voltage | Range | Resolution | Basic error |
|---|---|---|---|
| Output DC 100 V ± 10 % | 0–5 MΩ | 0.01 MΩ | — |
| 5–20 MΩ | 0.1 MΩ | — | |
| 20–50 MΩ | 0.1 MΩ | — | |
| 50–100 MΩ | 0.1 MΩ | — | |
| Output DC 200 V ± 10 % | 0–10 MΩ | 0.01 MΩ | — |
| 10–50 MΩ | 0.1 MΩ | — | |
| 50–100 MΩ | 0.1 MΩ | — | |
| 100–200 MΩ | 0.1 MΩ | — | |
| Output DC 500 V ± 10 % | 0–20 MΩ | 0.01 MΩ | — |
| 20–100 MΩ | 0.1 MΩ | — | |
| 100–200 MΩ | 0.1 MΩ | — | |
| 200–500 MΩ | 0.1 MΩ | — | |
| Output DC 1000 V ± 10 % | 0–200 MΩ | 0.1 MΩ | ±3 % rdg ± 5 dgt |
| 200–500 MΩ | 1 MΩ | ±3 % rdg ± 5 dgt | |
| 500 MΩ – 5 GΩ | 0.01 GΩ | ±3 % rdg ± 5 dgt | |
| 5–10 GΩ | 0.01 GΩ | ±5 % rdg ± 3 dgt | |
| Output DC 2500 V ± 10 % | 0–500 MΩ | 0.1 MΩ | ±3 % rdg ± 5 dgt |
| 500 MΩ – 1 GΩ | 1 MΩ | ±3 % rdg ± 5 dgt | |
| 1–10 GΩ | 0.01 GΩ | ±5 % rdg ± 3 dgt | |
| 10–100 GΩ | 0.1 GΩ | ±10 % rdg ± 3 dgt |
The ET3916R series multi-channel temperature testers (RTD / thermocouple type) offer a clear interface and flexible operation, and store large volumes of temperature data. They accept 10 thermocouple types (J, K, T, E, S, N, B, R, WRe3-25, WRe5-26) and 4 RTD types (PT1000, PT100, CU100, CU50), meeting production, laboratory and R&D measurement needs. Typical users include lighting appliances, power tools, household appliances, motors, electric heating appliances, pharmaceutical, petrochemical, chemical, metallurgy and electric power industries, and research institutes — production lines, laboratories and quality-inspection departments.
| Channels by model | ET3916R-06: 6 · ET3916R-12: 12 · ET3916R-18: 18 · ET3916R-24: 24 · ET3916R-30: 30 · ET3916R-36: 36 · ET3916R-48: 48 |
|---|---|
| Thermocouple electrical accuracy | 0.02 % FS |
| RTD electrical accuracy | 0.1 % FS |
| Display resolution | Up to 0.001 |
| Thermocouple measurement range | 78 mV |
| Cold-junction compensation accuracy | ±0.5 ℃ |
| Measurement speed | Slow 1 s/channel · medium 0.5 s/channel · fast 0.2 s/channel |
| Display modes | Numeric values, curves, bar graphs |
| Calibration | Independent correction coefficient per channel |
| Alarm | Independent alarm setting per channel (high-high, high, low, low-low) |
| Data recording interval | 1 s |
| Data storage | 8 GB TF card |
| Interfaces (standard) | USB Device, USB Host, RS232 · SCPI protocol |
| RTD type | Temperature range | Accuracy | Resolution |
|---|---|---|---|
| PT1000 | −200 to 650 ℃ | ±0.75 ℃ | 0.01 ℃ |
| PT100 | −50 to 850 ℃ | ±1 ℃ | |
| CU100 | −50 to 150 ℃ | ±1 ℃ | |
| CU50 | −50 to 150 ℃ | ±2 ℃ |
Accuracy excludes the RTD element's own error.
| Type | Temperature range | Accuracy | Resolution |
|---|---|---|---|
| K | −200 to 1372 ℃ | ±0.54 ℃ | 0.01 ℃ |
| J | −200 to 1100 ℃ | ±0.43 ℃ | |
| T | −100 to 400 ℃ | ±0.54 ℃ | |
| E | −50 to 830 ℃ | ±0.36 ℃ | |
| S | −50 to 1760 ℃ | ±1.00 ℃ | |
| N | −200 to 1300 ℃ | ±0.83 ℃ | |
| B | 600 to 1820 ℃ | ±1.15 ℃ | |
| R | −50 to 1768 ℃ | ±1.02 ℃ | |
| WRe3-25 | 0 to 1500 ℃ | ±1.90 ℃ | |
| WRe5-26 | 0 to 1500 ℃ | ±1.44 ℃ |
Accuracy excludes the thermocouple's own error and the cold-junction compensation error.
| Power supply | 220 Vac ±10 % or 110 Vac ±10 %, 45–65 Hz |
|---|---|
| Display | 5″ TFT LCD, resolution 854 × 480 |
| Operating temperature | 0–40 ℃ |
| Storage temperature | −10–70 ℃ |
| Relative humidity | < 80 % |
| Interfaces | USB Device, USB Host, RS232 (standard) |
| Dimensions | 260 × 300 × 100 mm (W × D × H) |
The ET3917 series multi-channel temperature testers (full-function type) offer a clear interface and flexible operation, and store large volumes of temperature data. They accept 10 thermocouple types (J, K, T, E, S, N, B, R, WRe3-25, WRe5-26) and 4 RTD types (PT1000, PT100, CU100, CU50), and additionally support 10 V and 100 V voltage inputs and a 20 mA current input, meeting production, laboratory and R&D measurement needs. Typical users include lighting appliances, power tools, household appliances, motors, electric heating appliances, pharmaceutical, petrochemical, chemical, metallurgy and electric power industries, and research institutes — production lines, laboratories and quality-inspection departments.
| Channels by model | ET3917-06: 6 · ET3917-12: 12 · ET3917-18: 18 · ET3917-24: 24 · ET3917-30: 30 · ET3917-36: 36 · ET3917-48: 48 |
|---|---|
| Thermocouple electrical accuracy | 0.02 % FS |
| RTD electrical accuracy | 0.1 % FS |
| Voltage accuracy | Up to 0.02 % FS — see voltage / current table |
| Current accuracy | 0.02 % FS — see voltage / current table |
| Display resolution | Up to 0.001 |
| Thermocouple measurement range | 78 mV |
| Voltage ranges supported | 10 V, 100 V |
| Current range supported | 20 mA |
| Cold-junction compensation accuracy | ±0.5 ℃ |
| Measurement speed | Slow, medium, fast (1 / 0.5 / 0.2 s per channel) |
| Display modes | Numeric values, curves, bar graphs |
| Calibration | Independent correction coefficient per channel |
| Alarm | Independent alarm setting per channel (high-high, high, low, low-low) |
| Data recording interval | 1 s |
| Data storage | 8 GB TF card |
| Interfaces (standard) | USB Device, USB Host, RS232 · SCPI protocol |
| RTD type | Temperature range | Accuracy | Resolution |
|---|---|---|---|
| PT1000 | −200 to 650 ℃ | ±0.75 ℃ | 0.01 ℃ |
| PT100 | −50 to 850 ℃ | ±1 ℃ | |
| CU100 | −50 to 150 ℃ | ±1 ℃ | |
| CU50 | −50 to 150 ℃ | ±2 ℃ |
Accuracy excludes the RTD element's own error.
| Type | Temperature range | Accuracy | Resolution |
|---|---|---|---|
| K | −200 to 1372 ℃ | ±0.54 ℃ | 0.01 ℃ |
| J | −200 to 1100 ℃ | ±0.43 ℃ | |
| T | −100 to 400 ℃ | ±0.54 ℃ | |
| E | −50 to 830 ℃ | ±0.36 ℃ | |
| S | −50 to 1760 ℃ | ±1.00 ℃ | |
| N | −200 to 1300 ℃ | ±0.83 ℃ | |
| B | 600 to 1820 ℃ | ±1.15 ℃ | |
| R | −50 to 1768 ℃ | ±1.02 ℃ | |
| WRe3-25 | 0 to 1500 ℃ | ±1.90 ℃ | |
| WRe5-26 | 0 to 1500 ℃ | ±1.44 ℃ |
Accuracy excludes the thermocouple's own error and the cold-junction compensation error.
| Input | Range | Accuracy | Resolution |
|---|---|---|---|
| Voltage 10 V | 10 V | ±0.002 V | 0.001 V |
| Voltage 100 V | 100 V | ±0.1 V | 0.01 V |
| Current 20 mA | 20 mA | ±0.004 mA | 0.001 mA |
| Power supply | 220 Vac ±10 % or 110 Vac ±10 %, 45–65 Hz |
|---|---|
| Display | 5″ TFT LCD, resolution 854 × 480 |
| Operating temperature | 0–40 ℃ |
| Storage temperature | −10–70 ℃ |
| Relative humidity | < 80 % |
| Interfaces | USB Device, USB Host, RS232 (standard) · relay alarm output optional |
| Dimensions | 260 × 300 × 100 mm (W × D × H) |
The ET3916 series multi-channel temperature testers (thermocouple type) offer a clear interface and flexible operation, and store large volumes of temperature data. They accept 8 thermocouple types (J, K, T, E, S, N, B, R), meeting production, laboratory and R&D measurement needs. Typical users include lighting appliances, power tools, household appliances, motors, electric heating appliances, pharmaceutical, petrochemical, chemical, metallurgy and electric power industries, and research institutes — production lines, laboratories and quality-inspection departments.
| Channels by model | ET3916-08: 8 · ET3916-16: 16 · ET3916-24: 24 · ET3916-32: 32 · ET3916-48: 48 · ET3916-64: 64 |
|---|---|
| Display | 5″ TFT high-definition LCD screen |
| Display digits | 6-digit data display, range up to 9999.99 (from −999.99) |
| Electrical measurement range | 64 mV |
| Electrical measurement accuracy | 0.05 % |
| Temperature display resolution | 0.1 ℃ |
| Thermocouple types supported | K, J, T, E, S, N, B, R |
| Measurement speed | Slow 1 s/channel · medium 0.5 s/channel · fast 0.1 s/channel |
| Synchronous display | Up to 32 channels on the numeric interface at once, with auto page-turning (multiple intervals) |
| Display modes | Numeric values, curves, bar graphs |
| Calibration function | Independent correction coefficient per channel |
| Alarm function | Independent alarm setting per channel (high-high, high, low, low-low) |
| Data recording interval | 1 s |
| Data storage | 8 GB memory |
| Operation | Built-in GB2312 character library, full-pinyin input |
| Interfaces (standard) | USB Device, USB Host |
| Interfaces (optional) | RS232 |
| Type | Temperature range | Accuracy | Resolution |
|---|---|---|---|
| K | −200 to 1372 ℃ | ±0.8 ℃ | 0.1 ℃ |
| J | −200 to 1100 ℃ | ±0.7 ℃ | |
| T | −100 to 400 ℃ | ±0.5 ℃ | |
| E | −50 to 830 ℃ | ±0.5 ℃ | |
| S | −50 to 1760 ℃ | ±0.2 ℃ | |
| N | −200 to 1300 ℃ | ±1 ℃ | |
| B | 600 to 1820 ℃ | ±2.4 ℃ | |
| R | −50 to 1768 ℃ | ±2.1 ℃ |
Accuracy excludes the thermocouple's own error and the cold-junction compensation error.
| Power supply | 220 Vac ±10 % or 110 Vac ±10 %, 45–65 Hz |
|---|---|
| Display | 5″ TFT LCD, resolution 854 × 480 |
| Operating temperature | 0–40 ℃ |
| Storage temperature | −10–70 ℃ |
| Relative humidity | < 80 % |
| Interfaces | USB Device, USB Host (standard) · RS232 optional |
| Dimensions | 260 × 300 × 100 mm (W × D × H) |
A compact auto-ranging handheld digital multimeter with true RMS measurement for electrical maintenance and field service. NCV and live-wire detection, a built-in flashlight and a backlit display cover panel and workshop checks.
| Display | 2000 counts · LCD 42.5 × 26 mm |
|---|---|
| DC voltage | 200 mV / 2 V / 20 V / 200 V / 600 V · ±(0.8 % + 5) |
| AC voltage | 2 V / 20 V / 200 V / 600 V · ±(1.2 % + 5) |
| Resistance | 200 Ω / 2 kΩ / 20 kΩ / 200 kΩ / 2 MΩ / 20 MΩ · ±(1.2 % + 8) |
| Temperature (℃) | −20 ℃ to 1000 ℃ · ±(2.0 % + 3) |
| Temperature (℉) | −4 ℉ to 1832 ℉ · ±(3.0 % + 3) |
| Range select | Auto range |
| Safety category | CAT III 600 V |
| Battery | 1.5 V (AAA) × 2 |
| Product size | 119 × 65 × 30 mm |
| Product weight | 130 g |
Programmable multi-channel DC power supplies for R&D benches and production lines — dual-channel models pair one adjustable output with a fixed 5 V / 2 A channel; triple-channel models offer two adjustable outputs plus the fixed channel. Models include ETP2303S, ETP3305S and ETP3605S.
| Configurations | Dual channel (CH1 adjustable + CH2 fixed 5 V / 2 A) · triple channel (dual adjustable + fixed 5 V / 2 A) |
|---|---|
| Models include | ETP2303S · ETP3305S · ETP3605S |
| Power range | 100–910 W |
| Display resolution | 1 mV / 1 mA |
| Interfaces | USB · RS232 |
Three-channel DC power supplies for service benches and electronics labs — two adjustable outputs plus a fixed 5 V / 3 A channel for logic and auxiliary circuits.
| Channels | CH1 / CH2 adjustable + CH3 fixed 5 V / 3 A |
|---|---|
| Ranges | 30 V (3 / 5 / 10 A) · 60 V (3 / 5 A) · 100 V (3 A) |
| Power range | 195–615 W |
| Display resolution | 10 mV / 1 mA |
| Interfaces | USB · RS232 |
The ETP-B series is a single-channel programmable DC stabilized power supply with a four-digit LED display. Constant-voltage (CV) and constant-current (CC) modes switch automatically, and output voltage and current limit are continuously adjustable. Advanced switch-mode control technology and components give high efficiency, light weight, energy saving and environmental friendliness. A 5 V / 2 A USB fast-charge function is available as an option.
| Item | ETP1506B | ETP1520B | ETP3005B | ETP3010B | ETP6003B | ETP6005B | ETP10003B | ETP15002B |
|---|---|---|---|---|---|---|---|---|
| Output voltage | 0 – 15 V | 0 – 15 V | 0 – 30 V | 0 – 30 V | 0 – 60 V | 0 – 60 V | 0 – 100 V | 0 – 150 V |
| Output current | 0 – 6 A | 0 – 20 A | 0 – 5 A | 0 – 10 A | 0 – 3 A | 0 – 5 A | 0 – 3 A | 0 – 2 A |
| Output power | 90 W | 300 W | 150 W | 300 W | 180 W | 300 W | 300 W | 300 W |
| CV mode | Voltage stability ≤ 0.1 % ± 3 mV · load stability ≤ 0.1 % ± 3 mV |
|---|---|
| CC mode | Current stability ≤ 0.1 % ± 3 mA · load stability ≤ 0.1 % ± 3 mA |
| Display accuracy | Voltage 0.5 % ± 3 digits · current 0.5 % ± 3 digits |
| Ripple and noise | Vpp ≤ 1 % |
| Display resolution | Voltage up to 10 mV · current up to 1 mA · power up to 10 mW |
| Display | 4-digit LED digital tube |
| Communication | RS232 standard · USB / RS485 optional · SCPI protocol |
| Power input | AC 220 V ± 10 % / 50 Hz or AC 110 V ± 10 % / 60 Hz (optional — to be specified before purchase) |
| Operating environment | Indoor use · altitude ≤ 2000 m · temperature 5 – 40 °C · humidity 10 % – 85 % RH |
| Storage environment | Temperature −20 – 80 °C · humidity ≤ 80 % RH |
| Dimensions | 190 × 115 × 150 mm (L × W × H) |
| Weight | Net 1.3 kg |
The ETP-A series is a single-output adjustable DC regulated power supply with a four-digit LED display that shows voltage and current simultaneously. Constant-voltage (CV) and constant-current (CC) modes switch automatically, and voltage and current are continuously adjustable. Advanced switch-mode control technology and components give high efficiency, light weight, energy saving and environmental friendliness.
| Item | ETP1503A | ETP1506A | ETP3003A | ETP3005A | ETP3010A | ETP6003A | ETP6005A |
|---|---|---|---|---|---|---|---|
| Output voltage | 0 – 15 V | 0 – 15 V | 0 – 30 V | 0 – 30 V | 0 – 30 V | 0 – 60 V | 0 – 60 V |
| Output current | 0 – 3 A | 0 – 6 A | 0 – 3 A | 0 – 5 A | 0 – 10 A | 0 – 3 A | 0 – 5 A |
| Output power | 45 W | 90 W | 90 W | 150 W | 300 W | 180 W | 300 W |
| CV mode | Voltage stability ≤ 0.1 % ± 3 mV · load stability ≤ 0.1 % ± 3 mV |
|---|---|
| CC mode | Current stability ≤ 0.1 % ± 3 mA · load stability ≤ 0.1 % ± 3 mA |
| Display accuracy | Voltage 0.5 % ± 3 digits · current 0.5 % ± 3 digits |
| Ripple and noise | Vpp ≤ 1 % |
| Display resolution | Voltage up to 10 mV · current up to 1 mA |
| Display | 4-digit LED digital tube |
| Power input | AC 220 V ± 10 % / 50 Hz or AC 110 V ± 10 % / 60 Hz (optional — to be specified before purchase) |
| Operating environment | Indoor use · altitude ≤ 2000 m · temperature 5 – 40 °C · humidity 10 % – 85 % RH |
| Storage environment | Temperature −20 – 80 °C · humidity ≤ 80 % RH |
| Dimensions | 190 × 70 × 130 mm (L × W × H) |
| Weight | Net 1.1 kg |
The ETP-C series is a single-channel DC regulated power supply with adjustable input voltage and adjustable output voltage and current; the external battery charging output is also adjustable. A 2.4-inch colour LCD, personalised settings and automatic CV / CC mode switching are built in. Advanced switching power-supply control technology and components give high efficiency, light weight and energy-saving, environmentally friendly operation. WiFi communication and 485 communication are available as options.
| Item | ETP6006C-PS | ETP6012C-PS | ETP6018C-PS | ETP6024C-PS |
|---|---|---|---|---|
| Input voltage | 6–70 V | |||
| Max. output voltage | (Input voltage ÷ 1.1) − 1 · up to 60 V | |||
| Output current | 0–6 A | 0–12 A | 0–18 A | 0–24 A |
| Output power | 0–360 W | 0–720 W | 0–1080 W | 0–1440 W |
| Voltage resolution | 0.01 V | |||
| Output current resolution | 0.001 A | 0.01 A | ||
| Input voltage accuracy | ±(1 % + 5 digits) | |||
| Output voltage accuracy | ±(0.3 % + 3 digits) | |||
| Output current accuracy | ±(0.5 % + 5 digits) | |||
| Battery voltage accuracy | ±(0.5 % + 3 digits) | |||
| Output ripple | 100 mV | 250 mV @ 6 A | 250 mV @ 6 A | 100 mV @ 12 A · 150 mV @ 24 A |
| Load regulation, CV mode | ±(0.1 % + 2 digits) | |||
| Load regulation, CC mode | ±(0.1 % + 3 digits) | |||
| External temperature sensor range | −10 ℃ to 100 ℃ / 0 ℉ to 200 ℉ | |||
| External temperature sensor error | ±3 ℃ / ±6 ℉ | |||
| Display | 2.4″ colour LCD, adjustable brightness |
|---|---|
| Interfaces | USB Type-C · WiFi optional · 232-to-485 module optional |
| Dimensions | 160 × 78 × 336 mm (L × W × H) |
| Weight | 1.3 kg |
The ETP-E series programmable multi-function DC power supplies deliver 450 W to 1800 W with a four-digit LED display showing voltage, current and power at the same time — clear, simple and easy to operate, with continuously adjustable, stable output. A 5 V / 2 A USB charging function is built in. Typical uses are hydro and thermal power plants, new-energy batteries, automated test systems, burn-in testing, quality inspection and serialized production testing.
| Model | Output voltage | Output current | Output power |
|---|---|---|---|
| ETP1530E | 0.01 – 15 V | 0.01 – 30 A | 450 W |
| ETP3015E | 0.01 – 30 V | 0.01 – 15 A | 450 W |
| ETP5010E | 0.01 – 50 V | 0.01 – 10 A | 500 W |
| ETP1005E | 0.01 – 100 V | 0.01 – 5 A | 500 W |
| ETP3020E | 0.01 – 30 V | 0.01 – 20 A | 600 W |
| ETP6010E | 0.01 – 60 V | 0.01 – 10 A | 600 W |
| ETP3030E | 0.01 – 30 V | 0.01 – 30 A | 900 W |
| ETP1560E | 0.01 – 15 V | 0.01 – 60 A | 900 W |
| ETP6015E | 0.01 – 60 V | 0.01 – 15 A | 900 W |
| ETP5020E | 0.01 – 50 V | 0.01 – 20 A | 1000 W |
| ETP2050E | 0.01 – 20 V | 0.01 – 50 A | 1000 W |
| ETP10010E | 0.01 – 100 V | 0.01 – 10 A | 1000 W |
| ETP6020E | 0.01 – 60 V | 0.01 – 20 A | 1200 W |
| ETP8015E | 0.01 – 80 V | 0.01 – 15 A | 1200 W |
| ETP5030E | 0.01 – 50 V | 0.01 – 30 A | 1500 W |
| ETP3050E | 0.01 – 30 V | 0.01 – 50 A | 1500 W |
| ETP15010E | 0.01 – 150 V | 0.01 – 10 A | 1500 W |
| ETP3060E | 0.01 – 30 V | 0.01 – 60 A | 1800 W |
| ETP6030E | 0.01 – 60 V | 0.01 – 30 A | 1800 W |
| ETP12015E | 0.01 – 120 V | 0.01 – 15 A | 1800 W |
| Stabilized voltage (CV) | Voltage stability ≤ 2 % · load stability ≤ 0.5 % |
|---|---|
| Stabilized current (CC) | Current stability ≤ 0.5 % · load stability ≤ 0.5 % |
| Preset accuracy | Voltage 0.1 V · current 0.1 A |
| Ripple and noise | Vpp ≤ 1 % |
| Voltage resolution | 0.01 V (below 100 V) · 0.1 V (100 V and above) |
| Current resolution | 0.01 A |
| Power resolution | 0.01 W (below 100 W) · 0.1 W (100 W and above) · 1 W (1000 W and above) |
| Standard interfaces | RS232, USB |
| Protocols | SCPI, Modbus |
| Power input | AC 220 V ± 10 % / 50 Hz, or AC 110 V ± 10 % / 60 Hz (optional — specify before purchase) |
| Operating environment | Indoor · altitude ≤ 2000 m · temperature 5–40 °C · humidity 10–85 % RH |
| Storage environment | Temperature −20 to 80 °C · humidity ≤ 80 % RH |
| Dimensions | 370 × 245 × 150 mm (L × W × H) |
| Weight | Net 4.7 kg |
No instruments in this field yet — ask by email or WhatsApp and we will check availability.
Support
Quoted individually — so model, options and freight fit your port or plant.
Ask for the model you are considering — you receive the full datasheet, available options, price and lead time before you decide.
Describe what you need to test, the range and where it will be used — the model is matched by application, and accuracy and accessory questions are answered before quoting.
Warranty and after-sales questions are handled by the VEROMET team — reach out any time by email or WhatsApp.
Email or WhatsApp the model number — or just describe what you need to test, the range and where it will be used.
You receive the full datasheet, available options, price and lead time. Questions on accuracy, inserts or accessories are answered before you decide.
Confirm the order details directly by email or WhatsApp and delivery is arranged to your address or your vessel's next port of call.
VEROMET is a China-based supplier of calibration and test instruments, serving marine service companies, calibration laboratories, distributors and industrial buyers worldwide. From our base in Zhejiang, we supply programmable DC electronic loads, LCR meters, DC power supplies, battery testers and signal measurement instruments for laboratories, production lines and battery service workshops, with export packing and worldwide delivery by express, air and sea freight.
Capabilities
More than 240 models across our calibration and measurement lines, from handheld instruments to bench systems.
Own-brand nameplates, manuals and packaging for distributors and ship-supply channels, including ordering by IMPA code for marine partners.
Every calibrator is tested before shipment and supplied with a calibration certificate.
Export packing as standard; worldwide delivery by express, air and sea freight, with DDP available on request.
12-month warranty on every instrument, with ongoing technical support from the team that supplied it.
Contact
Reach out by email or WhatsApp — whichever is easier. Sales contact: Kate Liu.
For quick questions and photos of the instrument you need to replace or match.
+86 139 5806 2364